3. Placing a jumper across the 1st and 2nd pins of the “3,4,5
UNLOCK” option allows User Code 3, User Code 4 and User Code
5 to activate (unlock) Relay #2
4. In this example, User Code 1 and User Code 2 have also been
given Latching Authorization for Relay #1.
Note: In order for 2 Door conguration to operate correctly, be sure to
remove any jumpers across the CCTV option and the Doorbell option.
Tamper Alarm Lockout
A person attempting to gain entry by guessing the code and pushing
25 wrong digits will cause the KE-265 to go into tamper alarm mode.
The Keypad will beep constantly for 30 seconds during which
time the door will remain locked and no keypad functions can be
performed.